Crashworthiness response of natural silk-fibre glass hybrid reinforced epoxy cylindrical composite tubes under quasi-static load

dc.contributor.authorUde, Albert Uchenna
dc.contributor.authorAzhari, Che Husna
dc.date.accessioned2021-10-15T12:15:53Z
dc.date.available2021-10-15T12:15:53Z
dc.date.issued2019-09
dc.description.abstractThis study investigated the failure behaviour, energy absorption response and load carrying capability of fibre-glass (FG)/natural silk fibre (NS)/epoxy hybrid composite cylindrical tubes subjected to an axial quasi-static compression test. The reinforced cylindrical composite tubes were prepared using mandrel assisted hand lay-up technique. The specimen tested were three (3) fibre-glass cylindrical tube, each consisting of 5 layers of (FG); three (3) natural-silk fibre cylindrical tubes, each consisting of 15 layers NS-fibre and FG/NS/epoxy hybrid cylindrical tubes, each consisting of 3 layers of FG, 9 layers of NS-fibres. The height of each tube was 50 mm; the thickness was 10 mm and the internal diameter was 65 mm. The energy absorption and load carrying ability of the tubes were analyzed by measuring specific energy absorption, maximum peak load (Pmax) and total energy absorption (TE) as a function of diverse fibre fraction under compressive loading. Failure mechanism of the tubes was analyzed from high resolution photographs obtained during test. As expected, FG/NS/epoxy hybrid tubes performed better in load carriability and energy attenuation while NS tubes performed better in progressive crushing failure behaviour. Deformation morphology suggests micro to macro cracks, tear propagation, delamination and collapseen_US
dc.description.accessibilityunrestricteden_US
dc.description.departmentmieen_US
dc.description.levelphden_US
dc.identifier.citationUde, A. U. and Azhari, C. H. (2019) Crashworthiness response of natural silk-fibre glass hybrid reinforced epoxy cylindrical composite tubes under quasi-static load. AIMS Materials Science, 6 (5), 852-863. doi: 10.3934/matersci.2019.5.852.en_US
dc.identifier.issn2372-0484
dc.identifier.urihttp://repository.biust.ac.bw/handle/123456789/366
dc.language.isoenen_US
dc.publisherAIMS Pressen_US
dc.subjectHybrid compositeen_US
dc.subjectEnergy absorptionen_US
dc.subjectCrashworthinessen_US
dc.subjectFailure mechanismen_US
dc.titleCrashworthiness response of natural silk-fibre glass hybrid reinforced epoxy cylindrical composite tubes under quasi-static loaden_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ude_AMS_2019.pdf
Size:
714.03 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: